SLIDE MOTOR INSPECTION


BHE091388662W01

1. Disconnect the slide motor connector.

2. Connect battery positive voltage to slide motor terminal A or B, then verify that the slide motor operate as shown in the table.

• If the slide motor does not operate as indicated in the table, replace the slide motor.

Motor operation

Connection

B+

GND

Forward
B
A
Backward
A
B