PASSENGER-SIDE AIR BAG MODULE CONSTRUCTION/OPERATION


BHE081057050T02

Inflator Operation

1. The igniter built into the inflator begins to build up heat when the operation (deployment) signal is sent from the SAS unit. The inflation agent is ignited by the build up of heat in the igniter.

2. The ignition of the inflation agent causes the combustion of an agent which releases nitrogen gas.

3. The nitrogen gas is cooled at the filter, and the filtrate is injected into the air bag.

1
Ignitor (inflator No.1)
2
Ignitor (inflator No.2)
3
Ignition of inflation agent
4
Gas generating agent
5
Gas generating agent combustion
6
Nitrogen gas
7
Filter
8
To air bag