SIMULATION FUNCTION


BHE050201026T08

• By using the WDS or equivalent, simulation items for input/output parts preset in the TCM can be optionally selected and operated regardless of TCM control conditions.

Simulation Item Table

X: Available

Simulation item

Applicable component

Unit/Condition

Operation

TCM terminal

IG ON

Idle

24B_Duty
Shift solenoid valve B (2-4 brake duty)
%
X
X
2S
HC_Duty
Shift solenoid valve C (high clutch duty)
%
X
X
2V
LRB_Duty
Shift solenoid valve F (low and reverse brake duty)
%
X
X
2P
LU_Duty
TCC solenoid valve (TCC solenoid duty)
%
X
X
2W
PCSV
Pressure control solenoid valve
ON/OFF
X
X
2X
TCCC
Shift solenoid valve A (low clutch duty)
%
X
X
2Y