SECONDARY SHUTTER VALVE (SSV) SWITCH REMOVAL/INSTALLATION


BHE014018990W02

1. Disconnect the SSV switch connector.

2. Remove the SSV installation screws and remove the SSV switch.

3. Install in the reverse order of removal.

SSV switch tightening torque
1.3-1.9 N·m {14-19 kgf·cm, 12-16 in·lbf}