SEQUENTIAL DYNAMIC AIR INTAKE SYSTEM (S-DAIS) STRUCTURE


BHE011300113T06

• The S-DAIS is composed of the SSV, VDI valve, and VFAD valve (13B-MSP (High Power)) which are opened and closed by intake manifold vacuum or BARO, and the APV (13B-MSP (High Power)) which is opened and closed by motor drive.

1
Illustration shows 13B-MSP (High power)
2
APV motor (13B-MSP (High power))
3
SSV actuator
4
SSV
5
VDI valve
6
VDI actuator
7
Intake manifold
8
APV (13B-MSP (High power))
9
Check valve
10
Vacuum chamber
11
SSV solenoid valve
12
VDI solenoid valve
13
VFAD solenoid valve(13B-MSP (High power))
14
Extension manifold
15
Check valve (13B-MSP (High power))
16
Vacuum chamber(13B-MSP (High power))
17
VFAD actuator (13B-MSP (High power))
18
VFAD valve (13B-MSP (High power))